Element4 Summum 140 4/S
View larger Four sides of glass.
A fire to arrange the room around.
- Fire view
- Four sides
- Model sizes
- 1
- Energy class
- A
Choose your setup
Summum size and viewing format
Front viewing opening: 1508 × 422mm
Viewing-opening dimensions, not the overall appliance or installation clearances.
Your selection is sent as an enquiry preference. The pictures retain the named model shown. Add any interior, glazing or left/right corner preference to your message; the team will confirm the complete specification and installation requirements.
View glazing and controlsPrice on request · installation quoted separately
Price on request. Contact our Macclesfield showroom to confirm the exact model, options and any display before travelling.
View larger The Summum 140 4/S has glass on all four sides, so it can become a central feature between different parts of a room. The structure above and below it is part of the installation: this is a built-in appliance, even when the finished design appears to stand independently. Plan the routes around the fire, the seating positions and the support arrangement together before settling on its position.
Compare the exact models
The opening
and the complete appliance.
Photographs show the named model in its manufacturer setting. Front viewing dimensions below describe the visible fire opening, not the overall appliance or the required construction space.

Element4 · Gas
Summum 140 4/S
Front viewing opening: 1508 × 422mm
Natural gas G20: 2.7 - 18.2 kW; propane G31: 3.7 - 18.5 kW. Published efficiency: 90%, energy class A. The drawing shows a 1586mm body width and 1610mm maximum overall width. The side viewing width is 302mm. Use the full model drawing for the appliance envelope and installation space.
Specify the details
Glazing, controls
and the finished setting.
Include any preferences with your enquiry. The quotation should identify the exact appliance, gas type and optional equipment.
Four-sided glazing
Glass on all four sides of the fire. The surrounding base and top construction form part of the installation design.
Anti-reflective glass
Available as an option in the current range. Ask for the appropriate glazing specification to be included in the quotation.
Controls and installation options
Remote control, app control and LED fire-bed lighting are listed as standard. Home automation, safety-screen and Powerfan options need checking against the exact appliance and installation.
Model-by-model figures
Dimensions and
gas performance.
Choose the row for the exact size and gas type. The front-opening measurements are kept separate from frame and body measurements.
| Fuel | Natural gas G20 or propane G31, in the correct appliance version |
|---|---|
| Fire view | Four-sided |
| Summum 140 4/S · G20 output range | 2.7 - 18.2 kW |
| Summum 140 4/S · G31 output range | 3.7 - 18.5 kW |
| Summum 140 4/S · efficiency / energy class | 90% / A |
| Summum 140 4/S · front viewing opening W × H | 1508 × 422mm |
| Body / maximum overall width | 1586 / 1610mm |
| Maximum depth shown in drawing | 405mm |
| Summum 140 4/S · side viewing width | 302mm |
| Flue collar in model drawings | 130 / 200mm concentric |
| Controls | Remote and app control listed as standard in the current manufacturer range |
| Burner / fire-bed lighting | Real Flame burner / LED lighting |
Figures follow the current Element4 gas pages and linked metric drawings. Output ranges differ by gas type; viewing dimensions are not installation clearances. The supplied appliance manual and an assessed flue design determine the installation.
For your home
Plan the fire
with the room.
Early measurements and photographs make the initial discussion more useful. A site assessment may still be required before the installation can be confirmed.
Leave room to move around it
Sketch the walking routes as well as the furniture. A central fire should be considered from every side, including the space needed around its finished enclosure.
Plan the support and flue early
The top structure and flue need a workable design before decorative finishes are chosen. The 4/S has its own drawing and should not be dimensioned from a front-facing Summum.
Discuss the complete project
Bring a room plan and photographs to our Macclesfield team. Include the proposed gas supply, ceiling construction and any planned building work so the next step can be assessed.
From Element4
Exact drawings.
The matching instructions.
Use the gas manual and metric drawing for the selected size and viewing format.
Summum 140 4/S · metric drawing
Exact viewing, frame and appliance measurements; not the finished enclosure size.
Summum 140 · gas installation manual
Instructions for this size, gas version, construction, servicing and approved flue arrangements.
Element4 · 2026 gas brochure
Current gas range, model photographs and published performance.
Explore Element4
Compare the viewing formats
Front, corner, three-sided and four-sided fires need different room layouts.

Element4 Summum F · 100 / 140 / 190

Element4 Summum C · 100 / 140 / 190

Element4 Summum 3/S · 100 / 140 / 190
A simple first step
Ask about your Summum 140 4/S
Your selected size and gas preference are included below. Add a room photograph, postcode and any glazing or corner-orientation requirements.
Prefer to talk? Call 01625 402900.
Macclesfield showroom
See it in person before you decide
Photographs only go so far. Come to the Macclesfield showroom to compare finishes, sizes and flame pictures side by side and talk through your room with the team.